Print Friendly, PDF & Email

LAN CABLE Cat6 SF/UTP

Fire resistance EN 50200 PH120
Flame retardant IEC 60332-3-24 Cat. C
Acid gas emission EN 60754-1  EN 60754-2
Smoke density EN 61034-2

Fire Standards

Our ‘Standard’ and ’Enhanced’ Fire cables are manufactured in the European Union in accordance with British Standards BS7629-1, BS EN 50200 PH30 / PH60 / PH120, BS7846 and BS6387 CWZ PH120.

We do supply LPCB & BASEC certified cables.

For more information, please visit Fire Standards

Cable construction
ConductorSolid plain annealed copper wire 22AWG/1
InsulationPolyolefin with mica glass for fire resistance
CablingThe insulated cores are cabled together in 4 pairs
Fire barrierGlass Tape
Overall shieldCopper drain wire/polyester tape/bare copper braid
Outer SheathLSZH thermoplastic compound, red
Nom. Outer diameter10.6mm
Electrical and Behaviour under fire conditions
Pair Capacitance65 pF/m
Impedance100 Ohms +/-15%
Fire resistanceEN 50200 PH120 (120min@840°C)
Flame retardantEN / IEC 60332-1-2
Corrosive acid gas ≤0.5%EN / IEC 60754-1 EN / IEC 60754-2
Smoke density (LT ≥60%)EN / IEC 61034-2
Max DC conductor resistance59,4 Ohms/km
Max operating voltage125 Vac
Min insulation resistance2,0 GOhms x km
Velocity of propagation66%
Delay skew20 nsec/100m
Accessories are available upon request, please contact a member of our sales team 0121 508 6890

fire-performance-accessories-blue

Fire Alarm & Emergency Standard 300/500V

SR 114H – 300/500 V (solid)

Posted in Fire Performance | Comments Off on Fire Alarm & Emergency Standard 300/500V

Fire Alarm & Emergency Enhanced 300/500V

SR 114E – 300/500 V (solid)

Posted in Fire Performance | Comments Off on Fire Alarm & Emergency Enhanced 300/500V

Fire Resistant LAN 300/500V

FIRE RESISTANT LAN CABLE

CAT6 SF/UTP

Posted in Fire Performance | Comments Off on Fire Resistant LAN 300/500V

Data Enhanced 300/500V

Data Enhanced 300/500 V

Posted in Fire Performance | Comments Off on Data Enhanced 300/500V

Mineral Insulated Fire Performance

FIRECEL MI are intended to be installed in critical safety circuits which are used to operate under fire conditions in severe applications where the mechanical cables performances are primarily required.

Posted in Fire Performance | Comments Off on Mineral Insulated Fire Performance

Fibre Optic Fire Performance

SLO-000-**-M1-A1-FR
SLO-000-**-M1-A3-FR
SLO-000-**-M1-A5-FR
SLO-000-**-M1-A7-FR

Posted in Fire Performance | Comments Off on Fibre Optic Fire Performance

Single Core Fire Performance 450/750V

SR 112 – Single Core Mica/XLPE Insulation
SR 112X – Twin Core Mica/XLPE Insulation
R-mXLSZH 450/750 V (600/1000 V for protected installation)

Posted in Fire Performance | Comments Off on Single Core Fire Performance 450/750V

Fire Performance Mains Cable Standard 600/1000V

Fire performance cables maintain circuit integrity in a fire and so are suitable for fire detection, alarm and emergency lighting systems.

Posted in Fire Performance | Comments Off on Fire Performance Mains Cable Standard 600/1000V

Fire Performance Mains Cable Enhanced 600/1000V

BS7846 – F120 (Enhanced)

Posted in Fire Performance | Comments Off on Fire Performance Mains Cable Enhanced 600/1000V