Print Friendly, PDF & Email

Connection Box CBO 5

General Data

  • Case material: Polyester, glass-fibre reinforced, halogen-free 
  • Ingress protection: IP 66 according to EN 60529:2000
  • Protection class: II – protective insulation according to VDE 0106
  • Impact resistance: IK 08, according to DIN EN 50102 (VDE 0470-100)
  • Case body: Grey, similar to RAL 7035
  • Case lid: Red, similar to RAL 3020
  • Gasket: Polyurethane
  • Mounting: Mounting screws outside of sealed enclosure interior
  • Operating temperature: -35 °C … +60 °C, up to +80 °C short term
  • Cable glands: Metric, with O-Ring
  • Weight: 0,48 … 0,55 kg (depending on configuration)
  • Dimensions: 130,0 x 130,0 x 74,7 mm, without cable glands (w x h x d)

Combustion behaviour

  • UL 94 V-2
  • UL50 5VA / UL 746C
  • EN 60695-11-10 / IEC 60695-11-10, 960 °C
  • VDE 0471 part 11-10, 960 °C
  • CSA C 22.2
Ordering Information

  • Connection Box CBO 5-SEC. Connection of up to two sensor cables SEC 15 and up to two connection cables CC 15 to SCU 800 port A or B
  • Connection Box CBO 5-ESD-T. TYPE1: Connection of up to two sensor cables SEC 15 and up to two connection cables CC 15 to SCU 800 port A or B. TYPE2: Connection of one sensor cable SEC15, Up to four external sensors ESD, and up to two connection cables CC 15 to SCU 800 port A or B. TYPE3: Connection of up to eight external sensors ESD and up to two connection cables CC15 to SCU800 port A or B.
  • Connection box CBO 5/1. Connection of up to two sensor cables SEC 15 and up to two connection cables CC 15 to SCU 800 port A or B
  • Connection Box CBO 5/2. Connection of two sensor cables Sec 15 and one connection cable CC15 each to SCU800 port A and B
Scope of Delivery

  • CBO 5-SEC,  including universal connection module UCM-SEC, mounting materials, metric cable glands and connection materials
  • CBO 5-ESD-T, including universal connection module UCM-ESD mounting materials, metric cable glands and connection materials
  • Connection Box CBO 5/1,including one connection module CCM 150-A materials, metric cable glands and connection materials
  • Connection Box CBO 5/2,including two connection modules CCM 150-A materials, metric cable glands and connection materials

Connection Box ATEX

Connection box for sensor cable SEC 15 and external sensors ESD in potentially explosive atmospheres (Zone 2 and 22).

Universal Connection Module UCM 15

Posted in SEC 15 | Comments Off on Universal Connection Module UCM 15

Connection Box CBO 15

Posted in SEC 15 | Comments Off on Connection Box CBO 15

d-LIST controller d-LCON

Posted in SEC 15 | Comments Off on d-LIST controller d-LCON

Accessories

Posted in SEC 15 | Comments Off on Accessories

Connection Box CBO 5

Posted in SEC 15 | Comments Off on Connection Box CBO 5

Connection Cable

Posted in SEC 15 | Comments Off on Connection Cable

Connection Module

Posted in SEC 15 | Comments Off on Connection Module

External Sensors

Posted in SEC 15 | Comments Off on External Sensors

Power Supply

Posted in SEC 15 | Comments Off on Power Supply

Remote Display Unit

Posted in SEC 15 | Comments Off on Remote Display Unit

SEC 15 Simulator

Posted in SEC 15 | Comments Off on SEC 15 Simulator

Sensor Cable

Posted in SEC 15 | Comments Off on Sensor Cable

Sensor Control Unit

Posted in SEC 15 | Comments Off on Sensor Control Unit

Software

Posted in SEC 15 | Comments Off on Software