SLO-000-**-M1-A1-FR

SLO-000-**-M1-A3-FR

SLO-000-**-M1-A5-FR

SLO-000-**-M1-A7-FR

These fire resistant, loose buffered, single tube, cables are mainly used inside buildings, tunnels or closed areas in general, are designed and manufactured to guarantee the signal transmission even in case of fire, thus safeguarding the operation of the safety systems or of particularly critical connections.

Cable Uses

  • Fire Fighting Systems
  • Hotels
  • Theatres and cinemas
  • Museums
  • Hospitals
  • Shopping centres
  • Undergrounds and Tunnels
  • Airports
  • Railway Stations
  • High-rise buildings
  • Data Communication Centres
  • Public Address Systems
  • Traffic Control Systems

 

Fire Standards

Our ‘Standard’ and ’Enhanced’ Fire cables are manufactured in the European Union in accordance with British Standards BS7629-1, BS EN 50200 PH30 / PH60 / PH120, BS7846 and BS6387 CWZ PH120. They are BASEC-approved and hold LPCB-certification. For more information, please visit Fire Standards

Cable construction
ConductorsPlain annealed copper wire, stranded according to EN 60228 class 2.
InsulationMica/Glass fire resistant tape covered by extruded cross-linked compound
type EI5
Operating temperatures-40°C to +90°C

General standards

Basic designBS 7211
Fire resistantBS 6387 (cat.C-W-Z tested in steel conduit)
Acid gas EmissionEN 50267-2-1 / IEC 60754-1
EN 50267-2-2 / IEC 60754-2
Smoke densityEN 61034-2 / IEC 61034-2

A3 Metallic armoured
TypeFibre
(n°)
Tube Diameter (mm)Diameter
(mm)
Weight
(kg/km)
Tension load
(N)
Crush
(N/100mm)
SLO-000-**-M1-A3-FR02 ÷ 122.79.010020004000
SLO-000-**-M1-A3-FR16 ÷ 243.510.012020004000

A5 Dielectric Armoured
TypeFibre
(n°)
Tube Diameter (mm)Diameter
(mm)
Weight
(kg/km)
Tension load
(N)
Crush
(N/100mm)
SLO-000-**-M1-A5-FR02 ÷ 122.77.57015003000
SLO-000-**-M1-A5-FR16 ÷ 243.58.08015003000

A7 Metallic armoured
TypeFibre
(n°)
Tube Diameter (mm)Diameter
(mm)
Weight
(kg/km)
Tension load
(N)
Crush
(N/100mm)
SLO-000-**-M1-A7-FR
02 ÷ 122.710.518025004000
SLO-000-**-M1-A7-FR16 ÷ 243.511.021025004000

Accessories are available upon request, please contact a member of our sales team 0121 508 6890

fire-performance-accessories-blue

Fire Alarm & Emergency Standard 300/500V

Print Friendly, PDF & Email

SR 114H – 300/500 V (solid)

Posted in Fire Performance | Comments Off on Fire Alarm & Emergency Standard 300/500V

Fire Alarm & Emergency Enhanced 300/500V

Print Friendly, PDF & Email

SR 114E – 300/500 V (solid)

Posted in Fire Performance | Comments Off on Fire Alarm & Emergency Enhanced 300/500V

Fire Resistant LAN 300/500V

Print Friendly, PDF & Email

FIRE RESISTANT LAN CABLE

Cat 5e STP

Posted in Fire Performance | Comments Off on Fire Resistant LAN 300/500V

Data Enhanced 300/500V

Print Friendly, PDF & Email

Data Enhanced 300/500 V

Posted in Fire Performance | Comments Off on Data Enhanced 300/500V

Mineral Insulated Fire Performance

Print Friendly, PDF & Email

FIRECEL MI are intended to be installed in critical safety circuits which are used to operate under fire conditions in severe applications where the mechanical cables performances are primarily required.

Posted in Fire Performance | Comments Off on Mineral Insulated Fire Performance

Fibre Optic Fire Performance

Print Friendly, PDF & Email

SLO-000-**-M1-A1-FR
SLO-000-**-M1-A3-FR
SLO-000-**-M1-A5-FR
SLO-000-**-M1-A7-FR

Posted in Fire Performance | Comments Off on Fibre Optic Fire Performance

Single Core Fire Performance 450/750V

Print Friendly, PDF & Email

SR 112 – Single Core Mica/XLPE Insulation
SR 112X – Twin Core Mica/XLPE Insulation
R-mXLSZH 450/750 V (600/1000 V for protected installation)

Posted in Fire Performance | Comments Off on Single Core Fire Performance 450/750V

Fire Performance Mains Cable Standard 600/1000V

Print Friendly, PDF & Email

Fire performance cables maintain circuit integrity in a fire and so are suitable for fire detection, alarm and emergency lighting systems.

Posted in Fire Performance | Comments Off on Fire Performance Mains Cable Standard 600/1000V

Fire Performance Mains Cable Enhanced 600/1000V

Print Friendly, PDF & Email

BS7846 – F120 (Enhanced)

Posted in Fire Performance | Comments Off on Fire Performance Mains Cable Enhanced 600/1000V